Field balancing of rotors in one and two planes |
■ |
Measurement of overall vibrations for evaluation of the machine condition |
■ |
Frequency analysis for identification of machine faults and damages |
■ |
Start-up and run-down analysis of the first harmonic for the detection of machine resonance's |
■ |
Envelope spectrum mesurements |
■ |
Display of the overall vibrations as well as of the first harmonic vs. time |
■ |
Visualization of vibration time-signature |
■ |
Bump test measurements |
■ |
Ball and roller bearing fault detection |
Technical Data
Measurement tasks
Measurement channels
■ |
2 channels for vibration |
■ |
1channel for rotor speed and reference signal |
Measurement values
■ |
Vibration displacement in µm |
■ |
Vibration velocity in mm/s |
■ |
Vibration acceleration in m/s2 |
Signal detection types
■ |
RMS value |
■ |
Peak-to-peak value |
■ |
Peak value |
Field balancing
■ |
Easy-to-understand operator dialog, integrated balancing calculator, polar presentation of unbalance and test run vectors and printed balancing reports via PC/Laptop |
■ |
Balancing rotor speed: 120 to 20,000 rpm |
■ |
Number of balancing planes: 1 or 2 |
■ |
Number of measuring points: up to 4 (enables optimized balancing procedures) |
■ |
Archiving of rotor influence coefficients to enable simplified balancing procedures in repeat situations |
■ |
Broadband vibration measurement in pre-selectable frequency ranges |
■ |
High-pass steps 2/5/10/20/50/ 100/200/500/1,000 Hz |
■ |
Low-pass steps 100/200/500/ 1,000/2,000/5,000/10,000 Hz |
■ |
Number of averages: 0 up to 100 |
Measurement of overall vibrations
Frequency analysis
■ |
Narrow band measurement for separation of the machine vibration into their harmonic portions |
■ |
FFT analysis, either without external trigger (free run) or with rotor-synchronous data acquisition |
■ |
High-pass steps: 5/10/20/50/100/200/500/1,000 Hz |
■ |
Low-pass steps: 100/200/500/1,000/2,000/5,000/10,000 Hz |
■ |
2/5/10/20 harmonic with rotor-synchronous data acquisition |
■ |
Resolution: 100/200/400/800 lines |
■ |
Number of averages: 0 to 100 |
■ |
Windowing functions: Hanning and Uniform (Rectangular) |
■ |
FFT analysis in the frequency range 5 to 10,000 Hz by means of 33 frequency bands with a constant relative bandwidth (26%) and with logarithmic graphical display |
Start-up and run-down analysis
■ |
Measurement, archiving and graphical display of the amplitude and the phase angle of the first harmonic in pre-selec-table rotor speed ranges |
■ |
Max. rotor speed range: 120 to 9,000 rpm |
■ |
Resolution: 100 lines |
Overall vibration and first harmonic vs. time
■ |
Measurement, archiving and graphical display of the characteristic values for overall vibration as well as for amplitude and phase angle of the first harmonic in pre-selectable time ranges |
■ |
Number of averages: 0 to 100 |
■ |
Number of depictable data sets: 5 to 100 |
■ |
Visualization of the vibration waveform |
■ |
Frequency range: 2 to 10,000 Hz, with rotor-synchronous data acquisition up to the 20 harmonic |
■ |
Sampling period: 2/5/10/20/ 50/100/200/500/ 1,000/2,000/5,000 ms |
■ |
Number of samples: 256/512/ 1,024/2,048 |
■ |
Number of averages with rotor-synchronous data acquisition: 0 to 100 |
■ |
Number of depictable data sets: 5 to 100 |
■ |
Resolution: 256/512/1,024/2,048 points |
Vibration time-signature
General features
■ |
Display: Monochrome LCD with 128 x 128 Pixel and backlit |
■ |
A/D-converter: 14 Bit resolutions |
■ |
Storage capacity of the internal EEPROM memory: 2 MB (for firmware and measurement data) |
■ |
Accuracy of the indicator unit: 5% |
■ |
USB interface for data upload to PC/Laptop |
■ |
With built-in rechargeable battery, storage capacity: 1,6 Ah |
■ |
Typical battery operation period: not less than 6 h |
■ |
Battery charge time: not more than 3 h |
■ |
Power and charger unit for 240 V, 50/60 Hz |
Power supply
■ |
Aluminium housing, rugged and shockproof design |
■ |
Protection class: IP 54 |
■ |
Operating temperature range: -10° to +50° C |
■ |
Relative air humidity: 0 to 95%, not condensing |
■ |
Dimensions: 220 x 110 x 38 mm |
■ |
Weight: 900 g |
Mechanical construction of the indicator unit
■ |
Dimensions: approx. 400 x 300 x 250 mm |
■ |
Weight incl. standard extent of delivery: approx. 5,4 kg |
Soft case